TAIHEI BOEKI
Pressure Switches
Z Series
New Z Series
TEX-Z Series
Main Menu
Z Series
General-Purpose Pressure Switches
TCZ Series
TDZ Series
Back
Diaphragm Actuated
TCZ Series
Model Lists
TCZ-5
TCZ-1
TCZ-2
Unit : MPa
Model |
Range |
Adjustable Dead Band
Low Range Mid. Range High Range |
Proof
Pressure |
TCZ-5 |
0.005 - 0.52 |
0.02 - 0.1 |
0.02 - 0.11 |
0.03 - 0.12 |
1.8 |
TCZ-1 |
0.005 - 1 |
0.03 - 0.2 |
0.04 - 0.21 |
0.05 - 0.22 |
3 |
TCZ-2 |
0.02 - 1.8 |
0.08 - 0.39 |
0.08 - 0.4 |
0.12 - 0.42 |
4 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Model Lists
TCZ-5F
TCZ-1F
TCZ-2F
Unit : MPa
Model |
Range |
Adjustable Dead Band
Low Range Mid. Range High Range |
Proof
Pressure |
TCZ-5F |
0.005 - 0.52 |
<= 0.02 |
<= 0.02 |
<= 0.03 |
1.8 |
TCZ-1F |
0.005 - 1 |
<= 0.03 |
<= 0.04 |
<= 0.05 |
3 |
TCZ-2F |
0.02 - 1.8 |
<= 0.08 |
<= 0.08 |
<= 0.12 |
4 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Model Lists
TCZ-5K
TCZ-1K
TCZ-2K
Unit : MPa
Model |
Range |
Outside
Adjustable Range |
Adjustable Dead Band
Low Range Mid. Range High Range |
Proof
Pressure |
TCZ-5K |
0.005 - 0.52 |
0 - 0.11 |
0.03 |
0.04 |
0.05 |
1.8 |
TCZ-1K |
0.005 - 1 |
0 - 0.21 |
0.05 |
0.08 |
0.09 |
3 |
TCZ-2K |
0.02 - 1.8 |
0 - 0.42 |
0.12 |
0.16 |
0.18 |
4 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Back
Piston Actuated
TDZ Series
Model List
TDZ-1
TDZ-3
TDZ-4
TDZ-7
TDZ-8
TDZ-13
TDZ-34
TDZ-47
TDZ-78


TDZ-4
Unit : MPa
Type |
Range |
Adjustable Dead Band
Low Range Mid. Range High Range |
Proof
Pressure |
TDZ-1 |
0.1 - 3.2 |
0.2 - 0.7 |
0.2 - 0.7 |
0.25 - 0.8 |
10 |
TDZ-3 |
0.2 - 7 |
0.25 - 1.3 |
0.28 - 1.4 |
0.3 - 1.5 |
35 |
TDZ-4 |
0.5 - 20.5 |
0.06 - 3.8 |
0.7 - 4 |
1.2 - 4.2 |
70 |
TDZ-7 |
1 - 40 |
1.4 - 7.8 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TDZ-8 |
2 - 63.5 |
2 - 11 |
2.5 - 12 |
3 - 12 |
120 |
TDZ-13 |
0.2 - 3.5 |
0.25 - 1.3 |
0.3 - 1.4 |
0.35 - 1.5 |
35 |
TDZ-34 |
0.5 - 10 |
0.6 - 3.8 |
0.7 - 3.8 |
1.2 - 4 |
70 |
TDZ-47 |
1 - 20 |
1.4 - 7.5 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TDZ-78 |
2 - 30 |
2 - 11 |
2.5 - 12 |
3.5 - 12 |
120 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Piston Actuated
Model List
TDZ-1K
TDZ-3K
TDZ-4K
TDZ-7K
TDZ-8K
Unit : MPa
Type |
Range |
Outside
Adjustable Range |
Adjustable Dead Band
Low Range Mid. Range High Range |
Proof
Pressure |
TDZ-1K |
0.1 - 3.2 |
0 - 0.7 |
0.25 |
0.3 |
0.35 |
10 |
TDZ-3K |
0.2 - 7 |
0 - 1.4 |
0.3 |
0.4 |
0.5 |
35 |
TDZ-4K |
0.5 - 20.5 |
0 - 4 |
0.8 |
1.1 |
1.3 |
70 |
TDZ-7K |
1 - 40 |
0 - 8 |
1.6 |
2 |
2.2 |
70 |
TDZ-8K |
2 - 63.5 |
0 - 12 |
3 |
3.5 |
4 |
120 |
Pressure Switch
Diaphragm Actuated
Model List
Z1.7D
Z005D
Z025D
Z035D
Z070D
Z120D
Z280D
Z1.7DW
Z005DW
Z025DW
Z035DW
Z070DW
Z120DW
Z280DW
Unit : MPa
Type of
Micro Switch |
Model |
Range |
Differential
Dead Band |
Rated Pressure |
Proof
Pressure |
SPDT |
Z1.7D |
0.002 - 0.17 |
0.003 |
2.3 |
3.5 |
SPDT |
Z005D |
0.005 - 0.5 |
0.005 |
2.3 |
3.5 |
SPDT |
Z025D |
0.02 - 2.5 |
0.025 |
7 |
12 |
SPDT |
Z035D |
0.05 - 3.5 |
0.05 |
10 |
41 |
SPDT |
Z070D |
0.1 - 7 |
0.12 |
12 |
41 |
SPDT |
Z120D |
0.2 - 12 |
0.2 |
15 |
41 |
SPDT |
Z280D |
0.2 - 28 |
0.7 |
35 |
42 |
|
|
|
|
|
|
DPDT |
Z1.7DW |
0.002 - 0.17 |
0.0045 |
2.3 |
3.5 |
DPDT |
Z005DW |
0.005 - 0.5 |
0.0075 |
2.3 |
3.5 |
DPDT |
Z025DW |
0.02 - 2.5 |
0.04 |
7 |
12 |
DPDT |
Z035DW |
0.05 - 3.5 |
0.075 |
10 |
41 |
DPDT |
Z070DW |
0.1 - 7 |
0.18 |
12 |
41 |
DPDT |
Z120DW |
0.2 - 12 |
0.3 |
15 |
41 |
DPDT |
Z280DW |
0.2 - 28 |
1 |
35 |
42 |
Differential Pressure Switch
Diaphragm Actuated
Model List
Z2.5DD
Z005DD
Z012DD
Z020DD
Z2.5DDEX
Z005DDEX
Z012DDEX
Z035DDEX
Z2.5DDW
Z005DDW
Z012DDW
Z020DDW
Z2.5DDWEX
Z005DDWEX
Z012DDWEX
Z035DDWEX
Unit : MPa
Type of
Micro Switch |
Model |
Range |
Dead Band |
Range of
Adjustable Difference |
Proof
Pressure |
SPDT |
Z2.5DD |
0.002 - 2 |
0.005 |
0.002 - 0.25 |
3.5 |
SPDT |
Z005DD |
0.005 - 2 |
0.01 |
0.005 - 0.5 |
3.5 |
SPDT |
Z012DD |
0.005 - 2 |
0.05 |
0.005 - 1.2 |
3.5 |
SPDT |
Z020DD |
0.005 - 2 |
0.07 |
0.005 - 2 |
3.5 |
SPDT |
Z2.5DDEX |
0.002 - 21 |
0.005 |
0.002 - 0.25 |
35 |
SPDT |
Z005DDEX |
0.005 - 21 |
0.01 |
0.005 - 0.5 |
35 |
SPDT |
Z012DDEX |
0.005 - 21 |
0.05 |
0.005 - 1.2 |
35 |
SPDT |
Z035DDEX |
0.005 - 21 |
0.07 |
0.005 - 2 |
35 |
|
|
|
|
|
|
DPDT |
Z2.5DDW |
0.002 - 2 |
0.0075 |
0.002 - 0.25 |
3.5 |
DPDT |
Z005DDW |
0.005 - 2 |
0.015 |
0.005 - 0.5 |
3.5 |
DPDT |
Z012DDW |
0.005 - 2 |
0.08 |
0.005 - 1.2 |
3.5 |
DPDT |
Z020DDW |
0.005 - 2 |
0.1 |
0.005 - 2 |
3.5 |
DPDT |
Z2.5DDWEX |
0.002 - 21 |
0.0075 |
0.002 - 0.25 |
35 |
DPDT |
Z005DDWEX |
0.005 - 21 |
0.015 |
0.005 - 0.5 |
35 |
DPDT |
Z012DDWEX |
0.005 - 21 |
0.08 |
0.005 - 1.2 |
35 |
DPDT |
Z035DDWEX |
0.005 - 21 |
0.1 |
0.005 - 2 |
35 |
Differential Pressure Switch
Diaphragm Actuated
Model List
Z1/4DD
Z1/4DDW
Unit : MPa
Type of
Micro Switch |
Model |
Range |
Dead Band |
Range of
Adjustable Difference |
Proof
Pressure |
SPDT |
Z1/4DD |
0.0005 - 6.6 |
0.0005 |
0.0005 - 0.025 |
10 |
|
|
|
|
|
|
DPDT |
Z1/4DDW |
0.0005 - 6.6 |
0.00075 |
0.0005 - 0.025 |
10 |
Differential Pressure Switch
Diaphragm Actuated
Model List
Z1/30DD
Unit : kPa
Type of
Micro Switch |
Model |
Range |
Dead Band |
Range of
Adjustable Difference |
Proof
Pressure |
SPDT |
Z1/30DD |
0 - 46 |
0.07 |
0 - 3 |
69 |
Explosion-proof Pressure Switch
(Diaphragm Actuator)
Model Lists
TEX1-Z005D
TEX1-Z010D
TEX1-Z018D
Unit : MPa
Model |
Range |
Differential Dead Band
Lower Range Middle Range Higher Range |
Rated
Pressure |
Proof
Pressure |
TEX1-Z005D |
0.005 - 0.5 |
0.03 - 0.1 |
0.03 - 0.11 |
0.04 - 0.12 |
0 - 0.5 |
1.8 |
TEX1-Z010D |
0.005 - 1 |
0.04 - 0.2 |
0.05 - 0.21 |
0.1 - 0.22 |
0 - 1 |
3 |
TEX1-Z018D |
0.02 - 1.8 |
0.09 - 0.39 |
0.12 - 0.4 |
0.2 - 0.42 |
0 - 1.8 |
4 |
Pressure Switches V Series
Diaphragm Actuated
Unit : MPa
Type |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TCV-5 |
0.005 - 0.52 |
0.02 - 0.1 |
0.02 - 0.11 |
0.03 - 0.12 |
1.8 |
TCV-1 |
0.005 - 1 |
0.03 - 0.2 |
0.04 - 0.21 |
0.05 - 0.22 |
3 |
TCV-2 |
0.02 - 1.8 |
0.08 - 0.39 |
0.08 - 0.4 |
0.12 - 0.42 |
4 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Pressure Switches V Series
Piston Actuated
Unit : MPa
Type |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TDV-1 |
0.1 - 3.2 |
0.2 - 0.7 |
0.2 - 0.7 |
0.25 - 0.8 |
10 |
TDV-3 |
0.2 - 7 |
0.25 - 1.3 |
0.28 - 1.4 |
0.3 - 1.5 |
35 |
TDV-4 |
0.5 - 20.5 |
0.06 - 3.8 |
0.7 - 4 |
1.2 - 4.2 |
70 |
TDV-7 |
1 - 40 |
1.4 - 7.8 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TDV-8 |
2 - 63.5 |
2 - 11 |
2.5 - 12 |
3 - 12 |
120 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Explosion Proof Pressure Switches TEX-SZ Series
Bellows Actuated
Unit : MPa
Type
SPDT DPDT |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
SPDT DPDT |
♣ Norminal
Pressure |
Proof
Pressure |
TEX1-SZ002B |
TEXW-SZ002BW |
0.005 - 0.2 |
0.008 - 0.04 |
0.012 - 0.04 |
0.2 |
0.3 |
TEX1-SZ006B |
TEXW-SZ006BW |
0.005 - 0.6 |
0.03 - 0.1 |
0.05 - 0.1 |
0.6 |
0.9 |
TEX1-SZ010B |
TEXW-SZ010BW |
0.005 - 1 |
0.06 - 0.2 |
0.08 - 0.2 |
1 |
2 |
TEX1-SZ025B |
TEXW-SZ025BW |
0.03 - 2.5 |
0.17 - 0.5 |
0.21 - 0.5 |
2.5 |
4.2 |
TEX1-SZ050B |
TEXW-SZ050BW |
0.1 - 5 |
0.5 - 0.9 |
0.65 - 0.9 |
5 |
14 |
TEX1-SZ115B |
TEXW-SZ115BW |
0.2 - 11.5 |
1.2 - 1.8 |
1.4 - 1.8 |
11.5 |
17.5 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Explosion Proof Pressure Switches TEX-Z Series
Piston Actuated
Unit : MPa
Type |
Adjustable Range |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TEX1-Z032P |
0.1 - 3.2 |
0.2 - 0.16 |
0.2 - 0.6 |
0.25 - 0.7 |
10 |
TEX1-Z070P |
0.2 - 7 |
0.25 - 1.3 |
0.28 - 1.4 |
0.3 - 1.5 |
35 |
TEX1-Z210P |
0.5 - 20.5 |
0.6 - 3.8 |
0.7 - 4 |
1.2 - 4.2 |
70 |
TEX1-Z400P |
1 - 40 |
1.4 - 7.8 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TEX1-Z635P |
2 - 63.5 |
2 - 11 |
2.5 - 12 |
3 - 12 |
120 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Explosion Proof Pressure Switches TEX-Z Series
SUS316L Bellows Actuated
Unit : MPa
Type |
Adjustable Range |
♠ Adjustable Deadband |
♣ Nominal
Pressure |
Proof
Pressure |
TEX1-Z002BS |
0.005 - 0.2 |
0.008 - 0.04 |
0.2 |
0.3 |
TEX1-Z006BS |
0.005 - 0.6 |
0.03 - 0.1 |
0.6 |
0.9 |
TEX1-Z010BS |
0.005 - 1 |
0.06 - 0.2 |
1 |
2 |
TEX1-Z025BS |
0.03 - 2.5 |
0.17 - 0.5 |
2.5 |
4.2 |
TEX1-Z050BS |
0.1 - 5 |
0.5 - 0.9 |
5 |
14 |
TEX1-Z115BS |
0.2 - 11.5 |
1.2 - 1.8 |
11.5 |
17.5 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Explosion Proof Pressure Switches TEX-Z Series
Special Diaphragm Actuated
Unit : kPa
Type |
Adjustable Range |
♠ Adjustable Deadband |
♣ Nominal
Pressure |
Proof
Pressure |
TEX1-Z1/4D |
3 - 25 |
2.5 - 8 |
0 - 25 |
300 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Explosion Proof Pressure Switches TEX-Z Series
Special & Vacuum - Bellows Actuated
Unit : MPa
Type |
Adjustable Range |
♠ Adjustable Deadband |
♣ Nominal
Pressure |
Proof
Pressure |
TEX1-Z001BR |
80vac - 100 |
10 - 40 |
100vac - 100 |
300 |
TEX1-Z005BR |
73vac - 500 |
20 - 100 |
100vac - 500 |
900 |
TEX1-Z009BR |
67vac - 900 |
40 - 200 |
100 vac - 900 |
2000 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.